Advertising
- Dmm 20 Digital Multimeter User Manual 98025
- Digital Multimeter Dmm
- Digital Multimeter Instruction Manual
- Digital Multimeter Reviews
Dmm Digital Multimeters are available at Mouser Electronics. Mouser offers inventory, pricing, & datasheets for dmm Digital Multimeters. Digital Multimeters Digital Multimeter (Pro-DMM) Enlarge Mfr. Part # 480-001. 200 mVDC, 2000 mVDC, 20 VDC, 200 VDC, 1000 VDC, 200 VAC, 750 VAC: 200 Ohms to 2000 kOhms: 45 Hz to 450 Hz: Manual: No Data.
SAFETY PRECAUTIONS/
- Digital multimeter, Owner’s manual. Read online or download PDF. Equus 3300 - Hands-Free DMM (10 MegOhm) User Manual. Manuals Directory ManualsDir.com - online owner manuals library. 4° to 140° F (- 20° to 60° C).
- Last Revised: 24 January 2018 121GW User Manual 9 INTRODUCTION Congratulations on purchasing the EEVblog 121GW multimeter. It's one of the most feature packed small form factor meters on the market, designed to provide maximum functionality in as little bench space as possible.
WARNINGS
•
This Digital Multimeter is intended for INDOOR USE ONLY.
•
Pay close attention to
WARNINGS stamped on the front and rear of the
meter's case. These warnings, as well as all warnings and precautions used
through out this manual, must be followed to avoid electric shock and/or per-
sonal injury.
through out this manual, must be followed to avoid electric shock and/or per-
sonal injury.
•
The RESPONSIBLE PARTY shall be made aware that, if the equipment is
used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
To prevent electrical shock and/or damage to the tester or the equipment under
test, observe the following safety precautions:
test, observe the following safety precautions:
•
DO NOT apply more than the rated voltage, as marked on the meter,
between terminals or between any terminal and earth ground.
between terminals or between any terminal and earth ground.
•
Use caution when working above 30V AC rms, 42 V peak, or 60 V DC. Such
voltages pose a shock hazard.
voltages pose a shock hazard.
•
To avoid false readings that could lead to possible electric shock or personal
injury, replace the batteries as soon as the low battery indicator
injury, replace the batteries as soon as the low battery indicator
displays.
•
Use ONLY those test leads or probes provided with the meter. DO NOT use third-
party test leads or probes.
party test leads or probes.
•
Always inspect the multimeter, test leads and any other accessories for dam-
age prior to every use. If any damage is found, do not use tester until repairs
are done.
age prior to every use. If any damage is found, do not use tester until repairs
are done.
•
Always consider electrical and electronic equipment to be ener-gized (live).
Never assume any equipment is de-energized.
Never assume any equipment is de-energized.
•
Never ground yourself when taking electrical measurements. Isolate yourself
from ground by using dry rubber insulating mats to cover all exposed/ground-
ed metal. Stand on rubber mats and wear dry clothing.
from ground by using dry rubber insulating mats to cover all exposed/ground-
ed metal. Stand on rubber mats and wear dry clothing.
SPECIFICATIONS
GENERAL SPECIFICATIONS AND FEATURES
•
3-½ digit LCD display (maximum reading of 2000)
•
Manual range control
•
Automatic negative (-) polarity indication
•
Automatic zero adjustment
•
Over range indicator (except 10 A function). Displays '1' on LCD
•
Low battery indicator. Displays battery symbol
on LCD
•
Safety standard: CE EMC/LVD. The meter is up to the standards of IEC1010
Pollution Degree 2, over voltage Category 2 (signifies protection against
transient impulses at the local level mains electrical supply).
Pollution Degree 2, over voltage Category 2 (signifies protection against
transient impulses at the local level mains electrical supply).
•
Equipment marked
is protected throughout by Double or Reinforced Insulation.
•
Operating environment:
Temperature - 32° to 104° F. (0° C to 40° C)
Humidity - Less than 80% relative humidity (non-condensing)
Altitude - up to 6562 ft (2000 meters)
Humidity - Less than 80% relative humidity (non-condensing)
Altitude - up to 6562 ft (2000 meters)
•
Storage environment:
Temperature - 4° to 140° F (- 20° to 60° C)
Humidity - Less than 90% relative humidity (non-condensing)
Humidity - Less than 90% relative humidity (non-condensing)
•
Power Supply: One 9-volt (6F22) battery
•
Fuse: 315mA/250V 5X20 mm (Radio Shack, GMA/217 series; #270-1046)
fuse
fuse
•
Dimensions:
Height - 5.50 in. (139 mm)
Width - 3.50 in. (89 mm)
Depth - 1.25 in. (32 mm)
Width - 3.50 in. (89 mm)
Depth - 1.25 in. (32 mm)
•
Weight (including batteries): approximately 5.7 oz (170 g)
ELECTRICAL SPECIFICATIONS
Accuracy of specifications in the following tables are based on an operating
temperature of 64°F to 82°F (18°C to 28°C) and a relative humidity of less than
75%.
temperature of 64°F to 82°F (18°C to 28°C) and a relative humidity of less than
75%.
Maximum voltage from V ma socket to COM socket is 500V AC/DC; from COM
socket to ground is 300V AC/DC.
socket to ground is 300V AC/DC.
DC VOLTS
RESISTANCE (OHMS)
DIODE TEST
DC AMPS
BATTERY TEST
AC VOLTS
TESTING PROCEDURES
A. AC/DC VOLTAGE MEASUREMENT
Range
Resolution
Accuracy
Overload
Protection
200
Ω
0.1
Ω
±(1% of reading
2K
Ω
1
Ω
+ 5 digits)
250V DC/AC RMS
20K
Ω
10
Ω
200K
Ω
100
Ω
20M
Ω
10K
Ω
±(2% of reading
+ 5 digits)
+ 5 digits)
Open Circuit Voltage: Approximately 3V
Function
Range Resolution
Accuracy
Overload
Protection
Diode test
1mV
0.5 ~ 0.8V
250V
DC/AC
RMS
DC/AC
RMS
Open Circuit Voltage: Approximately 2.8V
Forward Voltage Drop: Approximately 1mA
Forward Voltage Drop: Approximately 1mA
Range
Resolution
Accuracy
Overload
Protection
2000
µ
A
1
Dmm 20 Digital Multimeter User Manual 98025
µ
A
20mA
Digital Multimeter Dmm
10
µ
A
±(1.5% of reading
0.315A/250V fuse
200mA
100
µ
A
+ 5 digits)
10A
10mA
±(2% of reading
Get access to helpful solutions, how-to guides, owners' manuals, and product specifications for your Level U Headphones from Samsung US Support. View and Download Samsung Level Over manual online. Level Over Headphone pdf manual download. Headphone Samsung Level U PRO EO-BN920 User Manual (23 pages) Headphone Samsung EO-BG930 User Manual (805 pages) Headphone Samsung EO-PN900 User Manual. Cordless headphones. Get access to helpful solutions, how-to guides, owners' manuals, and product specifications for your Level Active Headphones from Samsung US Support. Samsung level over headphones manual.
Non-Protected
+ 5 digits)
Measuring time is equal to or less than 15 seconds and time
interval is equal to or over 15 minutes.
interval is equal to or over 15 minutes.
Range
Resolution
Overload Protection
Digital Multimeter Instruction Manual
1.5V
10mV
0.315A/250V fuse
9V
Overload
Range
Resolution
Accuracy
Protection
200V
100mV
±(1.2% of reading
500V DC or AC
500V
1V
+ 10 digits)
Frequency: 40-400Hz
OWNER’S MANUAL
DIGITAL MULTIMETER
MRP #93-0187
Range
Resolution
Accuracy
Overload
Protection
Protection
200mV
100
µ
V
230 Vrms
2V
1mV
Digital Multimeter Reviews
±(0.8% of reading
20V
10mV
+ 5 digits)
500V DC
200V
100mV
Ford mustang 2016 ecoboost manual user pdf. Find your owner manual, warranty, and other information here. Print, read or download a PDF or browse an easy, online, clickable version. Access quick reference guides, a roadside assistance card, a link to your vehicle’s warranty and supplemental information if available.
or AC
500V
1V
±(0.8% of reading
+ 5 digits
Input impedance: 10M
Ω
for all ranges.
- 1 -
- 2 -
WARNING
To avoid possible electric shock, instrument damage and/or equipment
damage, DO NOT attempt to measure voltages ABOVE 500V AC/DC or
take measurements if the voltage is unknown. 500V AC/DC between the
COM and V jacks is the maximum voltage that this instrument is
designed to measure. The 'COM' terminal potential should not exceed
300V AC/DC measured to ground.
damage, DO NOT attempt to measure voltages ABOVE 500V AC/DC or
take measurements if the voltage is unknown. 500V AC/DC between the
COM and V jacks is the maximum voltage that this instrument is
designed to measure. The 'COM' terminal potential should not exceed
300V AC/DC measured to ground.
Advertising
Popular Brands
Popular manuals
Multimeters are used in all areas of electronics to determine the voltage, amperage or resistance in an electrical circuit. They are available in two varieties, analog and digital. Analog versions are cheaper to buy and are fine for establishing a current, but if you need a level of accuracy, a digital version is much more suitable. They are very simple to use and can come in handy in many situations in amateur electronics.
Auto Range Multimeter
Insert batteries into the multimeter. The number and type of batteries required will vary from model to model.
Connect the wires to the multimeter. One will go into the COM, or Common, connection. The other will go into either the VΩmA or the 10A plug. The VΩmA socket is more commonly used, as the other is for high amp circuits.
Select what reading you want to take. Auto range multimeters have fewer options and are usually limited to V (volts), Ω (resistance) and A (amps).
Connect the wires from the multimeter across the electrical circuit to take a reading.
Switched Range Multimeter
Insert batteries into the multimeter. The number and type of batteries required will vary from model to model.
Connect the wires to the multimeter. One will go into the COM, or Common, connection. The other will go into either the VΩmA or the 10A plug. The VΩmA socket is more commonly used as the other is for high amperage circuits.
Select what reading you want to take. Switched range multimeters have the standard V, A and Ω options, but they can also be set to a range depending on the how high the readings will be. This gives you a much more accurate reading.
Connect the wires from the multimeter across the electrical circuit to take a reading.
Warning
Be careful, as you are dealing with live electrical circuits.